-
1 внутри
•Phenomena occurring in and outside the rocket...
•The core was placed inside (of) the tube.
•In the interior of the dielectric material between the condenser plates, such charges cancel out.
•Temporary shutoff of equipment within the plant...
•If z0 lies interior to the regular Jordan curve,...
•Within the carbon nucleus there are forces holding the positive protons together.
•The rocks present within the earth are subject to...
•There is a shielding within the cone.
•Nuclear fusion in the interior of stars...
* * *Внутри -- inside, inside of, on the inside; internal to; withinThe interface board is factory-mounted inside the housing.Pits were found at the OD of a 0.64-cm-thick purge pipe located inside of the gasifier.The exterior liquid covers the outlet on both the inside and outside.Internal to the test article, insulation blankets around the propellant tank were provided as a tank protection from thruster plume heating.The probe can be locked in any desired position within the column.Русско-английский научно-технический словарь переводчика > внутри
-
2 электрические характеристики НКУ
электрические характеристики НКУ
-
[Интент]Параллельные тексты EN-RU
The Standard IEC 60439-1 identifies the nominal characteristics to be assigned to each assembly, defines the environmental service conditions, establishes the mechanical requirements and gives prescriptions about:
• insulation
• thermal behaviour
• short-circuit withstand strength
• protection against electrical shock
• degree of protection of the enclosure
• installed components, internal separation and connections inside the assembly
• electronic equipment supply circuits.
Information specified under items a) and b) shall be given on the nameplate according to the Standard.
Information from items c) to t), where applicable, shall be given either on the nameplates or in the technical documentation of the manufacturer:
a) manufacturer ’s name or trade mark;
b) type designation or identification number, or any other means of identification making it possible to obtain relevant information from the manufacturer;
c) IEC 60439-1;
d) type of current (and frequency, in the case of a.c.);
e) rated operational voltages;
f) rated insulation voltages (rated impulse withstand voltage, when declared by the manufacturer);
g) rated voltages of auxiliary circuits, if applicable;
h) limits of operation;
j) rated current of each circuit, if applicable;
k) short-circuit withstand strength;
l) degree of protection;
m) measures for protection of persons;
n) service conditions for indoor use, outdoor use or special use, if different from the usual service conditions.
Pollution degree when declared by the manufacturer;
o) types of system earthing (neutral conductor) for which the ASSEMBLY is designed;
p) dimensions given preferably in the order of height, width (or length), depth;
q) weight;
r) form of internal separation;
s) types of electrical connections of functional units;
t) environment 1 or 2.
[ABB]Стандарт МЭК 60439-1 определяет номинальные характеристики НКУ, условия эксплуатации, требования к механической части конструкции, а также следующие параметры:
• изоляция;
• превышение температуры;
• прочность к воздействию тока короткого замыкания;
• защита от поражения электрическим током;
• степень защиты, обеспечиваемая оболочкой;
• комплектующие элементы, внутреннее разделение НКУ ограждениями и перегородками, электрические соединения внутри НКУ;
• требования к цепям питания электронного оборудования.
Информация, относящаяся к пунктам а) и b), должна быть указана на паспортной табличке, соответствующей данному стандарту.
Информация, приведенная в пунктах с) … d), должна быть указана либо на паспортной табличке, либо в технической документации изготовителя:
a) наименование изготовителя или товарный знак;
b) обозначение типа, условного номера или другого знака, позволяющих получить необходимую информацию от изготовителя;
c) МЭК 60439-1;
d) род тока (а для переменно тока и частота.);
e) номинальные рабочие напряжения;
f) номинальное напряжение изоляции (или указываемое изготовителем номинальное импульсное выдерживаемое напряжение);
g) номинальное напряжение вспомогательных цепей, если таковые имеются;
h) предельные отклонения параметров;
j) номинальный ток каждой цепи, если таковые приводят;
k) прочность к воздействию короткого замыкания;
l) степень защиты;
m) меры защиты персонала;
n) нормальные условия эксплуатации при внутренней или наружной установке, а также специальные условия эксплуатации, если они отличаются от нормальных.
Степень загрязнения, если она указывается изготовителем;
o) вид системы заземления (режим нейтрали), который был принят при проектировании НКУ;
p) размеры, приводимые в следующей последовательности: высота, ширина (или длина), глубина;
q) масса;
r) вид внутреннего разделения;
s) типы электрических соединений функциональных блоков;
t) окружающая среда 1 или 2.
[Перевод Интент]Тематики
- НКУ (шкафы, пульты,...)
EN
Русско-английский словарь нормативно-технической терминологии > электрические характеристики НКУ
-
3 масляный трансформатор
масляный трансформатор
Трансформатор с жидким диэлектриком, в котором основной изолирующей средой и теплоносителем служит трансформаторное масло
[ ГОСТ 16110-82]
масляный трансформатор
Трансформатор, магнитная система и обмотки которого погружены в масло
(МЭС 421-01-14)
[ ГОСТ 30830-2002]EN
oil-immersed type transformer
a transformer of which the magnetic circuit and windings are immersed in oi
[IEV number 421-01-14]FR
transformateur immergé dans l'huile
transformateur dont le circuit magnétique et les enroulements sont immergés dans l'huile
[IEV number 421-01-14]Oil transformers
The magnetic circuit and the windings are immersed in a liquid dielectric that provides insulation and evacuates the heat losses of the transformer.
This liquid expands according to the load and the ambient temperature. PCBs and TCBs are now prohibited and mineral oil is generally used. It is flammable and requires protective measures against the risks of fire, explosion and pollution.
The most commonly used protective measures are the DGPT or the DGPT2: Gas, Pressure and Temperature sensor with 1 or 2 sensing levels on the temperature. This system cuts off the LV load (1st level) then the HV supply (2nd level) when there is a fault inside the transformer. A holding tank is used to recover all the liquid dielectric.
Of the four types of immersed transformer: free breathing transformers, gas cushion transformers, transformers with expansion tank and transformers with integral filling, only the latter are currently installed.
[Legrand]Масляные трансформаторы
Магнитная система и обмотки трансформатора погружены в жидкий диэлектрик, служащий изоляцией и теплоносителем.
Жидкий диэлектрик изменяет свой объем в соответствии с нагрузкой трансформатора и температурой окружающей среды. Поскольку в настоящее время применение полихлорированных дифенилов и тетрахлорбифенилов запрещено, то в основном используют минеральное масло. Оно огнеопасно, поэтому необходимо принимать меры против возникновения пожара, взрыва и загрязнения окружающей среды.
Как правило, применяются системы DGPT (одноуровневые системы, использующие датчики газа, давления и температуры) или DGPT2 – двухуровневые системы. В случае возникновения аномального состояния трансформатора данные системы отключают нагрузку цепей низшего напряжения (первый уровень защиты), а затем питание обмотки высшего напряжения (второй уровень защиты). Активная часть трансформатора находится в баке и полностью покрыта жидким диэлектриком.
Существует четыре типа масляных трансформаторов: трансформаторы с системой свободного дыхания, трансформаторы с газовой подушкой между зеркалом масла и крышкой трансформатора, трансформаторы с расширительным баком и трансформаторы с гофрированным баком. В настоящее время применяют только трансформаторы последнего типа
[Интент]
[http://www.ramo-chelny.ru/konschasti.html]Масляный трансформатор:
- Шихтованный магнитопровод
- Обмотка низшего напряжения
- Обмотка высшего напряжения
- Трубчатый бак
- Термометр
- Переключатель регулировочных отводов обмотки высшего напряжения
- Ввод (проходной изолятор) обмотки низшего напряжения
- Ввод (проходной изолятор) обмотки высшего напряжения
- Расширительный бак

[http://transfcomplect.narod.ru/transformator.html]Тематики
Классификация
>>>EN
DE
FR
Русско-английский словарь нормативно-технической терминологии > масляный трансформатор
См. также в других словарях:
Building insulation materials — A selection of insulation materials can aid in building insulation. All of these are based on standard principles of thermal insulation. Materials used to reduce heat transfer by conduction, radiation or convection are employed in varying… … Wikipedia
Installing building insulation — Due to the variety of building insulation materials available and the various building elements that may require insulation, there are a number of ways of installing building insulation.Where to insulateWhere to insulate depends on where your… … Wikipedia
Building insulation — refers broadly to any object in a building used as insulation for any purpose. Whilst the majority of insulation in buildings is for thermal purposes, the term also applies to acoustic insulation, fire insulation, and impact insulation. Often an… … Wikipedia
Dynamic insulation — is a form of insulation where cool outside air flowing through the thermal insulation in the envelope of a building will pick up heat from the insulation fibres. Buildings can be designed to exploit this to reduce the transmission heat loss (U… … Wikipedia
Cellulose insulation — The word cellulose comes from the French word for a living cellule and glucose, which is sugar. Insulation is low thermal conductivity material used to separate the internal climate and sounds of a building from external climate and sounds.… … Wikipedia
Thermal insulation — The term thermal insulation can refer to materials used to reduce the rate of heat transfer, or the methods and processes used to reduce heat transfer.Heat energy can be transferred by conduction, convection, radiation or when undergoing a phase… … Wikipedia
External wall insulation — system= External wall insulation system (EWIS) a thermally insulated, protective, decorative exterior cladding system which consist of: *foamed polystyrene *mineral wool *polyurethane foam *mineral or synthetic plasterThermal insulation thickness … Wikipedia
Exterior insulation finishing system — Exterior insulation and finishing system (EIFS) is a type of building exterior wall cladding system that provides exterior walls with an insulated finished surface and waterproofing in an integrated composite material system. Contents 1… … Wikipedia
Cavity wall insulation — is used to reduce heat loss through a cavity wall by filling the air space with a porous material. This immobilises the air within the cavity (air is still the actual insulator), preventing convection, and can substantially reduce space heating… … Wikipedia
cavity wall insulation — UK US noun [uncountable] british a substance that is put into a cavity wall to keep heat inside a building Thesaurus: building materialshyponym farm buildings and structures where animals are kepthyponym … Useful english dictionary
cavity wall insulation — noun (U) a substance put inside a cavity wall to keep heat inside a building … Longman dictionary of contemporary English